6 Communication settings and guide of HMI connecting with controller
6.30 IDEC Corporation
Serial Communication
Series CPU Link Module Driver
MICRO SMART FC4A-C10R2 RS232 on the CPU unit IDEC MicroSmart
System configuration
Series CPU Link Module COMM Type Parameter Cable
MICRO
SMART
FC4A-C10R2 RS232 on the CPU unit RS232 Setting Your owner cable
Supported Device
Device Bit Address Word Address Format Notes
Internal Relay M0.0-127.7
------
DDD.O
Output Q0.0-30.7
------
DD.O
Input I0.0-30.7
------
DD.O
Data Register
------
D0-8199 DDDD
Counter(Current Value)
------
C_CV0-99 DD
Counter(Preset Value)
------
C_SV0-99 DD
Timer(Current Value)
------
T_CV0-99 DD
Timer( Preset Value) T_SV0-99 DD
Note: M address: 121 in the plc correspond to 12.1 in the Kinco HMIware.