6 Communication settings and guide of HMI connecting with controller
Device Bit Address Word Address Format Notes
Input Relay X 00-67
------ OO
Output Relay Y 00-67
------ OO
Auxiliary Relay M 000-511
------ DDD
Special Auxiliary Relay SM9000-9175
------ DDDD
Data register
------
D 000-3999
DDDD
Special Data Register
------
SD 9000-9599
DDDD
------
FD 4000-6999 DDDD
Note: bit devices don’t support batch, but word device can.
Fx3u
Device Bit Address Word Address Format Notes
Input Relay X000-377
------ OOO
Output Relay Y000-377
------ OOO
Timer Relay T_bit 000-511
------ DDD
Counter Relay C_bit 000-199
------ DDD
Data Register Relay D_bit 0.0-7999.F
------ DDDD.H
Status Relay S0000-4095
------ DDDD
Internal relay M0000-7679
------ DDDD
Special internal relay SM8000-8511
------ DDDD
Timer
------
T000-511
DDD
Counter
------
C000-199
DDD
Data register
------
D0000-7999
DDDD
Special Data Register
------
SD8000-8511
DDDD
Counter Memory(D Word)
------
C_dword200-255
DDD
Q00jCPU
Device Bit Address Word Address Format Notes
Counter coil CC0-1023
------
DDDD
Counter contact CS0-1023
------
DDDD
Timer coil TC0-2047
------
DDDD
Timer contact TS0-2047
------
DDDD
Special link Relay SB000-7FF
------
HHH
Link Relay B0000-1FFF
------
HHHH
Status Relay S0000-8191
------
DDDD
Edge Relay
V0000-2047
------
DDDD
Annunciator F0000-2047
------
DDDD
Latch relay L0000-8191
------
DDDD
- 193 -
Comentarios a estos manuales