5 Refresh kernel and rootfs
4. Set sw2 to on, sw1 to off on the back of the panel after refresh, you can touch calibrate in the mode.
Press the “+” until the panel show “TP adjust successful”, and then reset.
5. Make switches to default set and reset.
6. Re-download the project to panel.
5.2 Refresh by Ethernet port
1. Set
sw1 and sw2 to off on the back of the panel.
2. Connect the panel with USB cable and set IP address.
Open the Evmanager tool to click set. Select the USB Port in the “Communication Set” dialog box, and
then click “OK”. Click “Get” to get HMI IP information and set a new IP in “Refresh IP/port” box, then
click “Refresh”.