Radix DMC-4000T Instrucciones de operaciones Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 331
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
5 Refresh kernel and rootfs
Click “set” and set the IP in the “communication set” dialog box.
3. Set the IP OK, and then set sw1 to on, sw2 to off, at the same time to reset.
Click “Write kernel” and “Write rootfs”. If you can’t refresh, check the IP and the cable.
4. Set sw2 to on, sw1 to off on the back of the panel after refresh, you can touch calibrate in this mode.
Press the “+” until the panel show “TP adjust successful”, and then reset.
5. Set sw1 and sw2 to off on the back of the panel, and then reset.
5.3 Refresh by USB port
1. Set
the sw1 to on, sw2 to off on the back of the panel.
2. Open the EVManager tool to select “system operate”---“communication set”, set the USB Port before
refresh kernel and rootfs.
- 14 -
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 330 331

Comentarios a estos manuales

Sin comentarios